Err 11
Burnham
Air Proving or Fan Speed Fault
Boiler display shows “Err 11” and burner does not light, fan may run briefly
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Inducer fan speed out of range, Blocked or restricted combustion air path, Faulty fan speed sensor or Hall sensor, Loose fan wiring connector
How to Fix / Troubleshooting
Safety first: Turn off power and gas. Venting issues can be hazardous.
- Inspect inducer fan: Remove the front cover and visually inspect the combustion fan. Check for dust buildup, debris, or signs of water intrusion from condensate.
- Check fan wiring: Ensure the multi-pin connector from the fan to the control board is fully seated and free of corrosion.
- Verify vent and intake: Confirm that vent and intake pipes are clear and properly supported. Sagging pipes can collect condensate and restrict flow.
- Reset and test: Restore power and call for heat. Listen for abnormal fan noises. If Err 11 returns, the fan assembly or its speed sensor may need replacement by a technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Combustion Fan Assembly
Check Price on Amazon
We may earn a commission from links on this page.