Err 12
Burnham Flow Fault or Delta-T Out of Range

Boiler locks out with “Err 12” and may show abnormal supply/return temperature difference

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Circulator pump undersized or failed, Zone valves closed or stuck, Airlock in system piping, Clogged strainer or dirt separator

How to Fix / Troubleshooting

Safety first: Turn off power before working on pumps or valves. Hot water can cause burns.

  • Check circulator: On a call for heat, the main system pump should run. Feel the pump body; if it is hot but not moving water, it may be seized. If it is cold and silent, check power to the pump relay.
  • Verify zone valves: If you have motorized zone valves, confirm that the zone calling for heat is actually opening (lever moves or end switch clicks).
  • Bleed air: Air in the system can stop flow. Use purge valves or radiator bleeders to remove air until a steady stream of water flows.
  • Clean strainers: If your Burnham boiler has a system strainer or dirt separator, isolate it, relieve pressure, and remove the screen to clean out debris.
  • Reset and monitor: Restore power and call for heat. Watch supply and return temperatures; a very large difference may indicate continued flow problems that require professional balancing or pump replacement.