Err 14
Burnham
Control Voltage or Power Supply Fault
Boiler intermittently displays “Err 14” and may reboot or lose settings
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Unstable 120V supply, Loose neutral or ground, Failing internal transformer, Water intrusion into control compartment
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker before inspecting electrical connections.
- Check service switch and breaker: Ensure the boiler switch is on and the breaker is not tripping. If the breaker trips repeatedly, do not reset; call an electrician or technician.
- Inspect wiring connections: Remove the control panel cover and check that line, neutral, and ground wires are tight at the terminal block and control.
- Look for moisture: Check for signs of leaks above the control (from piping, relief valve, or condensate). Dry any moisture and correct the leak source.
- Use surge protection: If your area has frequent power fluctuations, consider having a surge protector or line conditioner installed by a professional.
- Replace control if needed: If Err 14 persists and other causes are ruled out, the internal power supply on the control board may be failing and require replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Boiler Control Board
Check Price on Amazon
We may earn a commission from links on this page.