Err 14
Burnham Control Voltage or Power Supply Fault

Boiler intermittently displays “Err 14” and may reboot or lose settings

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Unstable 120V supply, Loose neutral or ground, Failing internal transformer, Water intrusion into control compartment

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker before inspecting electrical connections.

  • Check service switch and breaker: Ensure the boiler switch is on and the breaker is not tripping. If the breaker trips repeatedly, do not reset; call an electrician or technician.
  • Inspect wiring connections: Remove the control panel cover and check that line, neutral, and ground wires are tight at the terminal block and control.
  • Look for moisture: Check for signs of leaks above the control (from piping, relief valve, or condensate). Dry any moisture and correct the leak source.
  • Use surge protection: If your area has frequent power fluctuations, consider having a surge protector or line conditioner installed by a professional.
  • Replace control if needed: If Err 14 persists and other causes are ruled out, the internal power supply on the control board may be failing and require replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Boiler Control Board