Possible Causes
Air in radiators, Sludge in system, Pump running at too low speed, Stuck radiator valves
How to Fix / Troubleshooting
Safety first: Radiators and pipes may be hot. Use a cloth when bleeding radiators to avoid scalds.
User-level checks:
- Bleed all radiators starting from the lowest floor; top up system pressure afterwards.
- Ensure all TRVs and lockshield valves are open.
- Check that the room thermostat is set high enough and that time controls are calling for heat.
Technical checks (qualified personnel):
- Check pump operation and speed setting; increase speed if necessary.
- Inspect and clean any system filter or magnetic filter on the return line.
- Consider powerflushing the system if sludge is severe.
- Balance the radiators by adjusting lockshield valves to ensure even heat distribution.
After improvements, verify that all radiators reach target temperature within a reasonable time.