E03
Chaffoteaux Flue Gas Safety / Flue Thermostat or Fume Sensor Intervention

Boiler attempts to start but shuts down with E03, fan may run briefly, no flame established.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked flue or terminal, Faulty flue gas thermostat, Faulty air pressure switch, Condensate trap or pipe blocked causing flue restriction

How to Fix / Troubleshooting

Safety first: Switch off the boiler and isolate electrical power. Do not operate the boiler if you suspect a flue gas problem; risk of carbon monoxide.

User-level checks:

  • Visually inspect the outside flue terminal for obstructions (ice, leaves, nests). Remove any visible blockage without dismantling the flue.
  • Check that the condensate pipe outlet is not frozen or blocked; thaw gently with warm (not boiling) water if frozen.
  • Reset the boiler and observe if E03 reappears.

Technical checks (qualified personnel only):

  • Inspect the entire flue system for correct assembly, slope, and obstructions; rectify any installation faults.
  • Test the flue gas thermostat or fume sensor for correct operation and replace if faulty.
  • Check the air pressure switch tubing for splits, blockages, or water ingress; replace tubing or switch as needed.
  • Verify fan operation and speed; ensure the fan is delivering adequate airflow.
  • Clean and check the condensate trap and internal condensate pathways.

Do not bypass or short any safety devices. If the cause cannot be clearly identified and rectified, leave the boiler off and call a certified technician.