E04
Chaffoteaux Water Pressure Fault / Low System Pressure

Boiler displays E04 and will not start; may occur intermittently when hot water or heating is demanded.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Insufficient system pressure, Faulty water pressure sensor, Leak in heating circuit, Faulty filling loop or isolation valves

How to Fix / Troubleshooting

Safety first: Ensure the boiler is cool before topping up pressure. Do not exceed the maximum pressure indicated on the boiler label.

User-level checks:

  • Check the pressure gauge on the boiler. If below about 1.0 bar (cold), top up using the filling loop as described in the Chaffoteaux user manual.
  • After filling to 1.0–1.5 bar, close the filling valves securely to prevent over-pressurisation.
  • Reset the boiler and check if E04 clears.
  • Inspect visible pipework and radiators for leaks (damp patches, green staining, or drips).

Technical checks (for qualified personnel):

  • Verify correct operation of the water pressure sensor or pressure switch; check wiring and replace the sensor if readings are unstable or incorrect.
  • Check the expansion vessel pre-charge and recharge or replace the vessel if the diaphragm has failed.
  • Inspect the safety valve for passing water to the discharge pipe; replace if it does not seal properly.
  • Locate and repair any hidden leaks in the heating circuit.

If pressure repeatedly drops after topping up, a leak or expansion vessel fault is likely and should be addressed by a heating engineer.