E08
Chaffoteaux
Condensate Drain Blocked / Condensate System Fault
Boiler locks out with E08, sometimes accompanied by gurgling noises, especially in cold weather.
Advertisements
Possible Causes
Frozen external condensate pipe, Blocked condensate trap, Incorrect condensate pipe fall, Debris in condensate siphon
How to Fix / Troubleshooting
Safety first: Turn off the boiler before working on the condensate system. Condensate is mildly acidic; wear gloves and eye protection.
User-level checks:
- Inspect the external condensate pipe for freezing (bulging or ice). Thaw gently with warm water or a warm cloth; do not use naked flames.
- Once thawed, reset the boiler and see if it operates normally.
Technical checks (qualified personnel):
- Remove and clean the condensate trap/siphon; flush out sludge and debris.
- Check that the condensate pipe has adequate fall and is correctly sized per Chaffoteaux installation instructions.
- Ensure the trap is refilled with clean water before refitting to maintain the seal.
- Inspect internal condensate channels in the heat exchanger for blockage and clean if accessible.
Consider upgrading or insulating the external condensate pipe to reduce the risk of future freezing.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Condensate Trap