E17
Chaffoteaux External Control / Communication Fault

Boiler shows E17, often related to external control or thermostat issues; boiler may not respond to room thermostat.

Advertisements

Possible Causes

Incorrect wiring of room thermostat, Faulty OpenTherm or eBUS connection, Broken external control cable, Incompatible control device

How to Fix / Troubleshooting

Safety first: Turn off power before altering any control wiring.

User-level checks:

  • Check that the room thermostat or programmer has power and is set to call for heat.
  • Replace batteries in wireless thermostats if applicable.

Technical checks (qualified personnel):

  • Verify wiring at the boiler control terminals matches the Chaffoteaux wiring diagram.
  • Temporarily link the boiler's room thermostat terminals (if allowed) to confirm the boiler responds without the external control.
  • Check continuity of the control cable and correct polarity for OpenTherm/eBUS connections.
  • Replace the faulty thermostat or interface module if communication cannot be restored.

After correction, test full operation with the external control in both heating on and off states.