E17
Chaffoteaux
External Control / Communication Fault
Boiler shows E17, often related to external control or thermostat issues; boiler may not respond to room thermostat.
Advertisements
Possible Causes
Incorrect wiring of room thermostat, Faulty OpenTherm or eBUS connection, Broken external control cable, Incompatible control device
How to Fix / Troubleshooting
Safety first: Turn off power before altering any control wiring.
User-level checks:
- Check that the room thermostat or programmer has power and is set to call for heat.
- Replace batteries in wireless thermostats if applicable.
Technical checks (qualified personnel):
- Verify wiring at the boiler control terminals matches the Chaffoteaux wiring diagram.
- Temporarily link the boiler's room thermostat terminals (if allowed) to confirm the boiler responds without the external control.
- Check continuity of the control cable and correct polarity for OpenTherm/eBUS connections.
- Replace the faulty thermostat or interface module if communication cannot be restored.
After correction, test full operation with the external control in both heating on and off states.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Room Thermostat Interface