Crown Condensate Management / Flue Termination Issue

Boiler flue terminal outside shows signs of condensate staining or dripping on the wall

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Improper flue slope back to boiler, Blocked condensate drain, Incorrect termination kit installation, Excessive flue length causing condensation

How to Fix / Troubleshooting

Safety: Condensate is mildly acidic. Wear gloves when handling.

  • Check flue slope: The horizontal flue should slope slightly back toward the Crown boiler so condensate drains to the trap, not outside. If it slopes outward, a professional must correct the piping.
  • Inspect condensate drain: Ensure the condensate trap and line are clear and draining freely.
  • Termination kit: Verify the outside termination is installed per the Crown manual, with proper clearances and orientation.
  • Seal wall penetration: Ensure the flue penetration is properly sealed to prevent condensate from running down the wall.