Crown
No Power to Boiler
Boiler will not start at all; display is blank and there are no lights or sounds
Advertisements
Possible Causes
Tripped circuit breaker, Blown internal fuse on Crown control board, Faulty service switch, Loose power wiring at boiler junction box
How to Fix / Troubleshooting
Safety: Before working on electrical components, turn off power at the main breaker panel.
- Check breaker: Locate the dedicated breaker for the Crown boiler and ensure it is in the ON position. Reset if tripped once; if it trips again, stop and call an electrician or technician.
- Verify service switch: Many boilers have a wall-mounted service switch nearby. Confirm it is ON.
- Inspect power connection: Remove the boiler's electrical junction box cover and verify that wire nuts are tight and no wires are burned or loose.
- Internal fuse: Some Crown controls have a replaceable fuse. With power off, inspect and replace only with the same type and rating if blown. If it blows again, a deeper fault exists.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Control Board Fuse
Check Price on Amazon