E13
Crown Weak Flame Signal

Boiler shows E13; may indicate ionization current too low or flame signal weak

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty burner, Poor grounding of boiler, Flame sensor partially shorted, Incorrect gas/air mixture

How to Fix / Troubleshooting

Safety: Turn off power and gas before opening the combustion chamber.

  • Clean flame sensor: Remove and clean the flame sensor rod with fine abrasive pad. Ensure the ceramic insulator is not cracked.
  • Inspect burner: Check the Crown burner surface for dust, lint, or corrosion. Lightly vacuum around the burner without damaging the mesh.
  • Check grounding: Verify the boiler's ground wire is securely attached to the chassis and that the supply outlet is properly grounded.
  • Reset and observe: Restore power and gas, reset the boiler, and observe ignition. If E13 persists, a technician should check combustion settings and replace the flame sensor if needed.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Flame Sensor
Check Price on Amazon