CTC
Control / Thermostat Overshoot
Boiler runs continuously and overshoots the room temperature setpoint.
Advertisements
Possible Causes
Room thermostat incorrectly located, Faulty room sensor, Incorrect control parameters, Stuck relay on external controller
How to Fix / Troubleshooting
Safety: Isolate power before working on control wiring.
- Check thermostat location: Ensure the CTC room sensor or thermostat is not near heat sources, direct sunlight, or draughts.
- Verify setpoints: Confirm that the room temperature setpoint and schedules are correctly programmed.
- Test thermostat (technician): Bypass the thermostat at the boiler terminals to see if the boiler stops. Replace the thermostat or controller if it fails to open the circuit when satisfied.
- Adjust control parameters: In the installer menu, fine-tune weather compensation curves or hysteresis settings to reduce overshoot.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Room Thermostat / Room Sensor
Check Price on Amazon