CTC
Flame Instability / Early Flame Loss
Boiler starts then shuts down after a few seconds without showing a specific error code.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Low gas pressure, Partially blocked burner, Faulty ionisation electrode, Flue or air intake restriction
How to Fix / Troubleshooting
Safety: Turn off gas and power. Only a qualified gas technician should adjust gas supply or burner settings.
- Check other gas appliances: If they also perform poorly, contact the gas supplier to check supply pressure.
- Inspect flue terminal: Ensure the flue and air intake are clear.
- Clean burner and electrodes (technician): Remove the burner and electrodes, clean them, and check for correct positioning.
- Measure gas pressure (technician): Check inlet and burner pressures at the CTC gas valve and adjust or replace components as required.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Ionisation Electrode
Check Price on Amazon