E03
CTC Air Pressure Switch / Fan Proving Fault

Boiler locks out with E03; fan may run but burner does not ignite.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked flue or air intake, Faulty air pressure switch, Blocked fan venturi or pressure tubing, Faulty fan motor

How to Fix / Troubleshooting

Safety: Switch off power and allow the boiler to cool. Do not operate the boiler with the combustion cover removed.

  • Check flue terminal: From outside, ensure the CTC concentric flue terminal is clear of obstructions (ice, leaves, plastic bags). Remove any blockage.
  • Inspect air intake: On room-sealed models, check that the air intake section of the flue is not blocked or crushed.
  • Check pressure tubes: Remove the front cover and locate the air pressure switch and silicone tubes. Ensure tubes are not split, kinked, or full of condensate. Clear or replace as needed.
  • Test fan operation (technician): With power restored, command heat and listen for the fan. If the fan does not start or is noisy, test supply voltage at the fan connector. Replace the fan assembly if seized or electrically open.
  • Air pressure switch test (technician): Using a manometer or multimeter, verify that the air pressure switch changes state when the fan runs. Replace the air pressure switch if it fails to operate within the specified pressure range.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Air Pressure Switch
Check Price on Amazon