E08
CTC Low Water Pressure / Pressure Switch Fault

Boiler shows E08 and stops; system pressure gauge is low or fluctuating.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Insufficient system water pressure, Leaks in heating circuit, Faulty water pressure sensor or switch, Blocked expansion vessel connection

How to Fix / Troubleshooting

Safety: Allow the boiler to cool before repressurising. Do not exceed the maximum system pressure stated on the CTC data plate.

  • Check pressure gauge: Look at the boiler's pressure gauge. If below the recommended cold pressure (often 1.0–1.5 bar), repressurise using the filling loop.
  • Repressurise system: Connect the filling loop (if detachable), open the valves slowly, and watch the gauge rise. Close the valves at the target pressure. Bleed radiators and top up again if needed.
  • Inspect for leaks: Walk around the property checking radiators, valves, and visible pipework for signs of water. Repair any leaks before repeated repressurising.
  • Check expansion vessel (technician): If pressure rises quickly when heating and then drops to zero when cool, the expansion vessel may be flat or waterlogged. Isolate, drain pressure, and check the vessel pre-charge with a tyre gauge. Recharge or replace the expansion vessel.
  • Pressure sensor/switch (technician): If pressure is correct but E08 persists, test the water pressure sensor or switch with a multimeter. Replace the sensor if readings are incorrect.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Water Pressure Sensor
Check Price on Amazon