E18
CTC
Frost Protection / Low Internal Temperature Fault
Boiler shows E18; internal temperature too low or frost protection active.
Advertisements
Possible Causes
Boiler installed in unheated space, Faulty internal frost sensor, Inoperative pump during frost cycle, Incorrect parameter settings
How to Fix / Troubleshooting
Safety: Ensure the area around the boiler is safe and free from freezing water hazards.
- Check ambient conditions: If the CTC boiler is in a garage or loft, ensure the space is adequately insulated and ventilated to prevent freezing.
- Verify frost settings: In the boiler's installer menu, confirm frost protection parameters are correctly set according to the CTC manual.
- Check pump operation: During frost demand, the pump should run. If not, test and replace the pump if necessary.
- Sensor test (technician): Check the internal frost sensor or NTC reading via diagnostics and compare with actual temperature. Replace the sensor if faulty.
Advertisements
Repair Difficulty
Easy