E18
CTC Frost Protection / Low Internal Temperature Fault

Boiler shows E18; internal temperature too low or frost protection active.

Advertisements

Possible Causes

Boiler installed in unheated space, Faulty internal frost sensor, Inoperative pump during frost cycle, Incorrect parameter settings

How to Fix / Troubleshooting

Safety: Ensure the area around the boiler is safe and free from freezing water hazards.

  • Check ambient conditions: If the CTC boiler is in a garage or loft, ensure the space is adequately insulated and ventilated to prevent freezing.
  • Verify frost settings: In the boiler's installer menu, confirm frost protection parameters are correctly set according to the CTC manual.
  • Check pump operation: During frost demand, the pump should run. If not, test and replace the pump if necessary.
  • Sensor test (technician): Check the internal frost sensor or NTC reading via diagnostics and compare with actual temperature. Replace the sensor if faulty.