E21
CTC Diverter Valve Position Fault

Boiler displays E21; diverter valve not reaching position or stuck.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Sticking diverter valve cartridge, Faulty diverter motor/actuator, Debris in hydraulic block, Wiring fault to diverter motor

How to Fix / Troubleshooting

Safety: Isolate power and close water isolation valves. Allow the boiler to cool.

  • Check symptoms: Note whether heating, hot water, or both are affected. Inconsistent switching between modes suggests diverter issues.
  • Inspect actuator: Locate the diverter valve motor on the hydraulic block of the CTC boiler. Check for signs of water ingress or corrosion.
  • Manual movement (technician): Remove the actuator and manually move the diverter spindle. If stiff or seized, the valve cartridge may need replacement.
  • Replace actuator or cartridge: If the motor does not drive correctly or the valve is stuck, replace the diverter motor and/or valve cartridge according to CTC instructions.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Diverter Valve Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements