E22
CTC Peripheral Short-Circuit Protection

Boiler shows E22; internal overcurrent or short-circuit detected on low-voltage outputs.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted pump or fan, Shorted external 230V output, Damaged wiring harness, Faulty PCB driver circuit

How to Fix / Troubleshooting

Safety: Isolate power. Do not repeatedly reset without finding the cause.

  • Visual inspection: Check all visible wiring inside the CTC boiler for signs of chafing, burning, or melted insulation.
  • Disconnect peripherals (technician): Disconnect non-essential loads (e.g. external pump, valves) one by one and power up to see if E22 clears, isolating the faulty component.
  • Test pump and fan: Measure resistance of the pump and fan windings. Replace any component with abnormally low resistance or visible damage.
  • PCB check: If all loads test OK, the PCB output stage may be damaged and require replacement.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control PCB
Check Price on Amazon