E24
CTC General Sensor Calibration Fault

Boiler shows E24; sensor readings inconsistent or out of range.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Multiple NTC sensors out of tolerance, Poor sensor contact with pipes, Incorrect sensor installation, PCB analogue input fault

How to Fix / Troubleshooting

Safety: Isolate power and allow the boiler to cool.

  • Compare sensor readings: In diagnostic mode, compare flow, return, and DHW temperatures with actual measured values using a thermometer.
  • Check sensor mounting: Ensure all NTC sensors are firmly attached to pipes or inserted in pockets with good thermal contact.
  • Replace suspect sensors (technician): Any sensor with readings significantly different from actual temperature should be replaced.
  • PCB check: If multiple new sensors still give inconsistent readings, the PCB analogue circuitry may be faulty and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

NTC Sensor Set
Check Price on Amazon