CTC
Poor Circulation / Short Cycling
Radiators are only lukewarm and the boiler cycles on and off rapidly.
Advertisements
Possible Causes
Pump running at too low speed, Blocked system filter, Sludge in radiators, Incorrect boiler output settings
How to Fix / Troubleshooting
Safety: Allow the system to cool before handling filters or valves.
- Check room controls: Ensure thermostatic radiator valves are open and the room thermostat is set above current room temperature.
- Clean system filter: If a magnetic or mesh filter is installed on the return to the CTC boiler, isolate, depressurise locally, and clean the filter element.
- Adjust pump speed (technician): Increase the pump speed setting to improve circulation through the system.
- Balance radiators: Throttle back lockshield valves on radiators closest to the boiler to encourage flow to distant radiators.
- Check boiler modulation settings (technician): In the installer menu, verify that maximum output is correctly set for the system size to reduce short cycling.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Primary Circulation Pump
Check Price on Amazon
We may earn a commission from links on this page.