CTC Poor Circulation / Short Cycling

Radiators are only lukewarm and the boiler cycles on and off rapidly.

Advertisements

Possible Causes

Pump running at too low speed, Blocked system filter, Sludge in radiators, Incorrect boiler output settings

How to Fix / Troubleshooting

Safety: Allow the system to cool before handling filters or valves.

  • Check room controls: Ensure thermostatic radiator valves are open and the room thermostat is set above current room temperature.
  • Clean system filter: If a magnetic or mesh filter is installed on the return to the CTC boiler, isolate, depressurise locally, and clean the filter element.
  • Adjust pump speed (technician): Increase the pump speed setting to improve circulation through the system.
  • Balance radiators: Throttle back lockshield valves on radiators closest to the boiler to encourage flow to distant radiators.
  • Check boiler modulation settings (technician): In the installer menu, verify that maximum output is correctly set for the system size to reduce short cycling.