E09
Defro Communication Fault Between User Interface and Main PCB

Boiler shows E09, no response to thermostat or control signals, sometimes intermittent.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose communication cable between Defro display panel and main PCB, Faulty Defro control panel (HMI), Faulty main control board on Defro boiler, Electrical interference or water ingress on low-voltage harness

How to Fix / Troubleshooting

Safety: Isolate power before removing the front panel or control covers.

  • Inspect display cable: Remove the front cover and locate the ribbon or data cable connecting the Defro user interface to the main PCB. Ensure both ends are fully seated.
  • Check for moisture: Look for signs of condensation or leaks dripping onto the control panel or PCB. If moisture is present, identify and fix the leak (e.g., from automatic air vent or pipe joint) before drying the electronics.
  • Power cycle: After reseating cables, leave the boiler powered off for 2–3 minutes, then restore power and check if E09 clears.
  • Professional diagnosis: If the fault persists, a technician should test the low-voltage communication bus and may need to replace either the Defro display module or the main PCB.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Defro main control board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements