E16
Defro Outdoor Temperature Sensor Fault

Boiler displays E16, outdoor temperature not recognized, weather compensation not working.

Advertisements

Possible Causes

Open-circuit or shorted Defro outdoor sensor, Damaged cable between outdoor sensor and boiler, Incorrect sensor type fitted to Defro weather-compensated system, Loose terminal connection on control board

How to Fix / Troubleshooting

Safety: Isolate power before working on wiring. Outdoor work may require a ladder; take appropriate precautions.

  • Locate outdoor sensor: Find the Defro outdoor temperature sensor on an external wall, usually on the north or shaded side.
  • Inspect cable: Check the cable for cuts, UV damage, or rodent damage along its route to the boiler.
  • Check terminals: At the boiler, open the control panel and verify that the outdoor sensor wires are firmly clamped in the designated terminals.
  • Bypass test (for technicians): A professional can temporarily substitute a known-good resistor to simulate a valid temperature and confirm sensor failure.
  • Replace if needed: If the sensor is faulty, replace it with a genuine Defro outdoor temperature sensor of the correct resistance curve.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Defro outdoor temperature sensor
Check Price on Amazon