EHC
DHW Priority / Flow Detection Issue
Boiler provides central heating but no domestic hot water (on combi models).
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty DHW flow sensor, Stuck diverter valve in heating position, Blocked plate heat exchanger, DHW NTC sensor fault
How to Fix / Troubleshooting
Safety: Hot water circuits can become very hot; isolate power and water before disassembly.
User checks:
- Check that cold water supply to the boiler is on and that other cold taps work.
- Run a hot tap fully open and observe if the boiler attempts to fire.
Engineer checks:
- Test the DHW flow sensor/turbine on the EHC combi boiler; clean or replace if not detecting flow.
- Inspect and clean the plate heat exchanger if blocked by scale or sludge.
- Check diverter valve movement and replace actuator or cartridge if stuck.
- Verify DHW NTC sensor readings.
After repair, test multiple hot water outlets to confirm stable temperature and flow.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Plate Heat Exchanger
Check Price on Amazon