EHC Lockout without Displayed Code

Boiler starts then shuts down after a few seconds without showing a specific error code.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Intermittent flame detection, Loose sensor connections, PCB relay fault, Unstable gas supply

How to Fix / Troubleshooting

Safety: Intermittent faults can be hazardous if related to combustion. Do not ignore repeated shutdowns.

User checks:

  • Observe any pattern (e.g. only on hot water, only when windy) and report to the engineer.
  • Ensure gas supply is not being interrupted by other appliances.

Engineer checks:

  • Check flame sensor and ignition electrode connections on the EHC boiler.
  • Monitor gas pressure during operation for dips or fluctuations.
  • Inspect PCB for dry joints or intermittent relays; replace PCB if confirmed faulty.

Accurate diagnosis may require extended observation and use of manufacturer diagnostic modes.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Flame Sensor (Ionisation Probe)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements