E03
EHC Fan or Air Pressure Switch Fault

Boiler locks out with E03, fan may not start or stops quickly, no ignition attempt.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty fan motor, Blocked flue or condensate trap, Faulty air pressure switch, Split or blocked pressure tubing

How to Fix / Troubleshooting

Safety: Turn off power before removing the boiler front panel. Do not run the boiler with the case removed.

User checks:

  • Visually inspect the flue terminal outside for obstructions (leaves, nests, snow).
  • Check the condensate pipe for freezing in cold weather; thaw gently with warm (not boiling) water if frozen.

Engineer checks:

  • Confirm the fan receives correct voltage from the PCB when there is a demand; if voltage is present but the fan does not run or is noisy, replace the fan assembly.
  • Inspect and clear the condensate trap and internal condensate hoses on the EHC boiler.
  • Check the air pressure switch tubing for splits, kinks or blockages; replace tubing if hardened or damaged.
  • Test the air pressure switch for correct operation with a manometer or continuity tester; replace if it does not switch at the specified pressure.
  • Inspect the flue system for correct installation, slope and integrity.

Do not bypass the air pressure switch; it is a critical safety device. Replace faulty components with EHC-approved parts.