E09
EHC
Water Circulation / Pump Fault
Boiler shows E09 and will not run, often associated with pump or flow issues.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Seized or failed circulation pump, Airlock in primary circuit, Blocked system filter or strainers, Closed isolation valves
How to Fix / Troubleshooting
Safety: Turn off power and allow the system to cool before working on the pump or pipework.
User checks:
- Verify system pressure is adequate (1.0–1.5 bar cold).
- Bleed radiators to remove trapped air.
Engineer checks:
- Check that the EHC boiler pump receives power when there is a demand; if powered but not running, free the pump shaft or replace the pump.
- Bleed the pump via the bleed screw to remove air.
- Inspect any magnetic filter or strainer on the return for sludge; clean thoroughly.
- Ensure all isolation valves around the boiler and pump are open.
After restoring circulation, reset the boiler and monitor operation to confirm E09 does not return.