E10
EHC Low System Water Pressure

Boiler displays E10, pressure gauge shows very low or zero pressure, boiler will not fire.

Advertisements

Possible Causes

Insufficient water in sealed system, Leak in heating circuit, Faulty pressure sensor or switch, Faulty filling loop or valves

How to Fix / Troubleshooting

Safety: Allow the system to cool before topping up. Do not over-pressurise.

User procedure:

  • Locate the filling loop on your EHC boiler or nearby pipework (usually a braided hose with two valves).
  • Open both valves slowly and watch the pressure gauge rise to 1.0–1.5 bar.
  • Close both valves firmly and reset the boiler.
  • Check for visible leaks around radiators, valves and under the boiler. If pressure drops again, a leak must be found and repaired.

Engineer checks:

  • Test the pressure sensor or switch for correct operation.
  • Inspect the expansion vessel charge; recharge or replace if failed, as this can cause frequent pressure loss.

If you are unsure how to use the filling loop, consult the EHC manual or a heating engineer.