E15
EHC
Air in System / Dry Fire Protection
Boiler shows E15 and shuts down, often accompanied by gurgling noises or partial heating.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Insufficient system filling, Air trapped in heat exchanger, Faulty automatic air vent, Incorrect pump speed or orientation
How to Fix / Troubleshooting
Safety: Allow boiler to cool before bleeding air. Protect surrounding area from water spills.
User checks:
- Check system pressure and top up to 1.0–1.5 bar if low.
- Bleed radiators starting from the lowest to highest points.
Engineer checks:
- Bleed the boiler’s internal automatic air vent and ensure its cap is loosened as per EHC instructions.
- Bleed the circulation pump and high points in the primary circuit.
- Check that the pump is correctly sized and set to an appropriate speed.
- Replace a faulty automatic air vent if it is leaking or not releasing air.
After removing air, reset the boiler and monitor for recurrence of E15.