E16
EHC
Diverter Valve Position Fault
Boiler intermittently shows E16, particularly when switching between heating and hot water.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Sticking diverter valve, Faulty diverter motor/actuator, Scale or debris in valve body, Faulty position microswitch or sensor
How to Fix / Troubleshooting
Safety: Isolate power and water before working on the diverter valve assembly.
User checks:
- Observe whether heating or hot water is failing when E16 appears and note the pattern for the engineer.
Engineer checks:
- Locate the diverter valve on the EHC combi boiler hydraulic block.
- Manually exercise the valve (if possible) to free any sticking mechanism.
- Remove and inspect the diverter cartridge for scale or debris; clean or replace as needed.
- Test the diverter motor/actuator for correct operation and replace if weak or inoperative.
- Check any position switches or sensors for continuity and correct signalling to the PCB.
After repair, test both heating and hot water modes to ensure smooth changeover without E16 reoccurring.