Nuisance Tripping / Overcurrent
Boiler frequently trips the main breaker or RCD when heating starts.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Overloaded circuit, Earth leakage from elements, Shorted wiring, Incorrect breaker rating for boiler load
How to Fix / Troubleshooting
Safety first: Do not repeatedly reset a tripping breaker; identify and correct the cause. Isolate the boiler before inspection.
- Confirm circuit rating: Check that the breaker and cable size are appropriate for the boiler's kW rating and phase configuration as per Elnur installation instructions.
- Inspect wiring: Look for signs of overheating, melted insulation, or loose terminals at the boiler and isolator.
- Test elements for earth leakage: Use an insulation tester to check each element to earth. Replace any element with low insulation resistance.
- Check for moisture: Ensure there are no leaks dripping onto electrical components. Repair leaks and dry components thoroughly.
- Upgrade protection (if needed): If the boiler load is within spec but the breaker is underrated, have a qualified electrician upgrade the protective device and cabling as required.