E10
Elnur Temperature Out-of-Range / Sensor Calibration Fault

Boiler displays E10; may indicate sensor out-of-range or internal temperature too low/high for normal operation.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

NTC sensor drift, Poor thermal contact between sensor and pipe, Incorrect sensor type fitted, PCB analogue input fault

How to Fix / Troubleshooting

Safety first: Turn off power before handling sensors or wiring.

  • Compare displayed temperature: Check the boiler's displayed temperature against an external thermometer on the flow pipe. Large discrepancies suggest sensor or contact issues.
  • Inspect sensor mounting: Ensure the NTC sensor is firmly clamped to the pipe or fully inserted into its pocket with thermal paste if specified.
  • Check sensor type: If the sensor was replaced, verify that the correct Elnur part number and resistance curve have been used.
  • Test resistance: Measure sensor resistance at a known temperature and compare with the manufacturer's chart. Replace if out of tolerance.
  • PCB input check: If multiple sensors read incorrectly, the PCB's analogue input circuit may be faulty and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Primary NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements