VENT BLOCK
Energy Kinetics Blocked Vent or Flue Safety Trip

Control indicates VENT BLOCK or BLOCKED FLUE; burner shuts down and will not restart until cleared.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Obstructed chimney or vent pipe, Blocked intake on direct vent models, Tripped blocked vent switch, Failed vent pressure switch

How to Fix / Troubleshooting

Safety: A blocked vent can cause carbon monoxide buildup. If you suspect flue gases in the living space, evacuate and call emergency services. Do not operate the boiler until the vent is verified clear.

  • 1. Visual inspection: From a safe location, inspect the vent termination and intake (if applicable) for snow, leaves, nests, or debris. Clear any obvious obstructions.
  • 2. Check blocked vent switch: Some Energy Kinetics boilers have a manual reset blocked vent switch on the flue. After clearing the vent and allowing the boiler to cool, press the reset button once.
  • 3. Do not bypass safeties: Never jumper or bypass a vent safety switch to keep the boiler running.

If the VENT BLOCK error returns, a professional must inspect the chimney, venting system, and draft.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Blocked Vent Switch / Vent Pressure Switch
Check Price on Amazon

We may earn a commission from links on this page.