Possible Causes

Incorrect gas valve adjustment, Blocked or partially blocked flue, Fan speed issues, Burner contamination

How to Fix / Troubleshooting

Safety first: Abnormal combustion noise can indicate unsafe operation. Do not ignore it.

  • User checks: Ensure the flue terminal is not obstructed from outside.
  • Engineer actions:
    • Perform a full combustion analysis with a flue gas analyser.
    • Adjust gas valve and CO₂ settings to Ferroli specifications.
    • Inspect and clean the burner and combustion chamber.
    • Check fan speed and flue integrity.