A03
Ferroli Safety Thermostat Intervention / Overtemperature Lockout

Boiler locks out with A03 shortly after starting; may be accompanied by very hot return pipe and no heat to radiators.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked or scaled primary heat exchanger, Stuck or closed system valves, Faulty pump or low circulation, Faulty safety thermostat

How to Fix / Troubleshooting

Safety first: Isolate electrical power and allow the boiler to cool. Do not repeatedly reset an overheating boiler.

  • Check radiator valves: Ensure at least a few radiators are fully open; all TRVs closed can cause poor circulation and overheating.
  • Check system pressure: Confirm pressure is within the recommended range (typically 1.0–1.5 bar cold). Re-pressurise if needed.
  • Reset once: After cooling, perform a single reset. If A03 returns, stop using the boiler and call an engineer.
  • Engineer checks:
    • Verify pump speed and operation; replace if not circulating properly.
    • Inspect and clean or replace the primary heat exchanger if restricted.
    • Test the safety thermostat and NTC sensors with a multimeter.
    • Check for closed isolation valves on the flow/return under the boiler.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Safety Thermostat / Overheat Cut-out
Check Price on Amazon