A04
Ferroli Low Water Pressure / Insufficient System Water

Boiler displays A04 and will not start; may be associated with low or zero pressure on the gauge.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

System pressure below minimum, Leak in heating circuit, Faulty pressure sensor, Faulty filling loop or PRV passing

How to Fix / Troubleshooting

Safety first: Allow the system to cool before topping up pressure to avoid scalding from hot water.

  • Check pressure gauge: If below 0.8 bar (cold), top up via the filling loop to 1.0–1.5 bar following the Ferroli manual.
  • Bleed radiators: After topping up, bleed radiators to remove air, then re-check and adjust pressure.
  • Inspect for leaks: Look around radiators, valves, and under the boiler for visible water. Any continuous pressure loss indicates a leak that must be repaired.
  • If pressure is correct but A04 persists: The pressure sensor or wiring may be faulty; do not bypass safety devices.
  • Engineer checks:
    • Test and replace the water pressure sensor if readings are incorrect.
    • Check the expansion vessel charge and recharge or replace if failed.
    • Locate and repair any hidden leaks in the system.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Water Pressure Sensor
Check Price on Amazon