A05
Ferroli
Flue Gas / Air Pressure Switch Fault
Boiler shows A05 and shuts down; may occur intermittently during operation, often related to flue or air issues.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked flue or condensate, Faulty air pressure switch, Blocked venturi or fan housing, Faulty fan
How to Fix / Troubleshooting
Safety first: Turn off power and do not operate the boiler if you suspect flue blockage or fumes. Risk of carbon monoxide.
- Visual flue check (user level): From outside, ensure the flue terminal is clear of obstructions (ice, leaves, nests). Do not dismantle the flue yourself.
- Check condensate pipe: In freezing weather, ensure the external condensate pipe is not frozen or blocked. Thaw gently with warm (not boiling) water if frozen.
- Reset once: After clearing obvious obstructions, reset the boiler. If A05 returns, stop using the boiler.
- Engineer checks:
- Test the air pressure switch tubing and connections for blockages or splits.
- Verify correct operation of the fan and replace if not achieving required speed.
- Inspect and clean the venturi and flue gas path.
- Replace the air pressure switch if faulty.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Air Pressure Switch