A06
Ferroli Flame Instability / Flame Loss During Operation

Boiler locks out with A06; may start then stop with no stable flame, often in windy conditions or with flue issues.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect gas pressure, Faulty gas valve modulation, Blocked burner, Faulty flame sensing electrode or PCB

How to Fix / Troubleshooting

Safety first: Isolate the boiler from the mains and gas supply before any internal inspection. Gas work must be done by a qualified engineer.

  • Check other gas appliances: If they also fail or burn weakly, contact your gas supplier.
  • Reset the boiler: Perform a reset according to the manual. If the fault recurs, do not keep resetting.
  • Engineer checks:
    • Measure inlet and burner gas pressures and adjust or replace the gas valve as needed.
    • Inspect and clean the burner and combustion chamber.
    • Check the flame sensing electrode and lead; replace if damaged or readings are low.
    • Verify PCB flame detection circuitry and replace PCB if necessary.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Gas Valve
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements