A10
Ferroli
DHW Temperature Sensor (NTC) Fault
Boiler shows A10 and stops; often related to domestic hot water (DHW) temperature sensing issues on combi models.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed DHW NTC sensor, Scale build-up around DHW sensor pocket, Loose sensor connection, PCB sensor input fault
How to Fix / Troubleshooting
Safety first: Isolate power and water before removing covers or sensors.
- Check DHW operation: Run a hot tap and observe if the boiler attempts to fire before A10 appears. Intermittent firing suggests sensor issues.
- Engineer checks:
- Measure DHW NTC resistance and compare to spec.
- Inspect the sensor pocket for scale; descale or replace as needed.
- Replace the DHW NTC sensor if readings are unstable.
- Check wiring and PCB for faults if sensor tests good.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
DHW NTC Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements