A21
Ferroli Control Board / User Interface Communication Fault

Boiler shows A21; often related to communication or configuration issues between control board and user interface.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose harness between PCB and display, Faulty user interface board, Main PCB fault, Incorrect parameter configuration

How to Fix / Troubleshooting

Safety first: Isolate power before removing the front panel or accessing electronics.

  • Power reset: Turn off the boiler at the fused spur for 2–3 minutes, then power back on. This can clear transient communication errors.
  • Check for moisture: Ensure there are no signs of water ingress on the front panel or around the boiler that could affect electronics.
  • Engineer checks:
    • Inspect and reseat the low-voltage harness between the main PCB and display.
    • Check for damaged tracks or components on the user interface board.
    • Replace the user interface or main PCB if communication cannot be restored.
    • Verify and reprogram boiler parameters if corrupted.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main PCB (Control Board)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements