F02
Ferroli
Temperature Sensor Fault (Generic)
Boiler displays F02; may be associated with NTC sensor faults depending on model.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective NTC sensor, Short or open circuit in sensor wiring, Incorrect sensor fitted, PCB sensor input failure
How to Fix / Troubleshooting
Safety first: Turn off power and allow the boiler to cool before touching sensors or pipework.
- Reset: Perform a reset. If F02 returns, a hardware fault is likely.
- Engineer checks:
- Identify which NTC (flow, return, or DHW) is referenced by F02 in the specific Ferroli model manual.
- Measure sensor resistance and compare to the temperature/resistance chart.
- Inspect wiring and connectors for damage or corrosion.
- Replace the faulty NTC sensor or PCB as required.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
NTC Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements