F62
Ferroli Delayed Ignition / Gas Valve Closure Fault

Boiler shows F62; may indicate delayed ignition or gas valve closing fault.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Gas valve not closing promptly, PCB control fault, Incorrect gas pressure, Slow ignition sequence

How to Fix / Troubleshooting

Safety first: Delayed ignition can cause loud bangs and is dangerous. Do not operate the boiler until checked.

  • User action: Turn off gas and power to the boiler.
  • Engineer checks:
    • Inspect and test gas valve closing time; replace if sluggish.
    • Check ignition sequence and electrode condition.
    • Verify gas pressures and adjust as per Ferroli data.
    • Replace PCB if control fault is identified.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Gas Valve
Check Price on Amazon