Fondital
Insufficient DHW Capacity / Flow Limitation
Boiler does not produce hot water when more than one tap is opened
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Flow restrictor in Fondital boiler limiting output, Scaled DHW plate heat exchanger, Low incoming cold water pressure, Gas rate set too low
How to Fix / Troubleshooting
Safety: None specific, but avoid relying on hot water for critical tasks until resolved.
User checks:
- Use one tap at a time: Test hot water with only one outlet open to see if temperature improves.
- Check cold pressure: Ensure cold water pressure at taps is adequate.
Technician actions:
- Check and clean the DHW inlet filter and any flow restrictor.
- Descale or replace the DHW plate heat exchanger.
- Verify gas valve settings and maximum DHW output on the Fondital PCB.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
DHW Plate Heat Exchanger
Check Price on Amazon
We may earn a commission from links on this page.