Fondital
Heating Demand / Diverter Valve Fault
Boiler does not respond to heating demand, but hot water works normally
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck diverter valve on Fondital combi boiler, Faulty room thermostat or wiring, Diverter motor failure, PCB not receiving heating demand signal
How to Fix / Troubleshooting
Safety: Turn off power before touching any control wiring.
User checks:
- Thermostat settings: Ensure the room thermostat is calling for heat and set above room temperature.
- Programmer: Check that the heating program is active and not in OFF or holiday mode.
- Boiler mode: Confirm the Fondital boiler is not set to DHW-only mode.
Technician actions:
- Test the room thermostat and wiring to the boiler.
- Check operation of the diverter valve motor and replace if stuck or seized.
- Inspect the diverter valve cartridge for debris and replace if worn.
- Verify the main PCB is correctly processing heating demand.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Diverter Valve Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements