Fondital Control Logic / Sensor Placement Issue

Boiler frequently goes into anti-cycling or anti-freeze mode even when not required

Advertisements

Possible Causes

Incorrectly placed external sensor on Fondital system, Faulty room thermostat or remote control, PCB parameter misconfiguration, NTC sensor drift

How to Fix / Troubleshooting

Safety: No direct hazard, but may waste energy.

User checks:

  • Thermostat location: Ensure the room thermostat or remote control is not near heat sources or in direct sunlight.
  • Program settings: Review heating schedules and anti-freeze settings on the Fondital controller.

Technician actions:

  • Check and, if necessary, relocate the room thermostat or external sensor.
  • Verify and adjust PCB parameters (anti-cycling time, anti-freeze thresholds) according to Fondital documentation.
  • Test NTC sensors for drift and replace if out of tolerance.