Fondital Short Cycling / Oversized Boiler or Sensor Misreading

Boiler runs for only a short time then stops, radiators never reach set temperature

Advertisements

Possible Causes

Flow temperature set too high on Fondital boiler, Incorrect NTC sensor readings, Poor system volume or missing bypass, Pump over-speed causing rapid temperature rise

How to Fix / Troubleshooting

Safety: No immediate hazard, but efficiency is reduced.

User checks:

  • Lower flow temperature: Reduce the heating flow temperature setting to around 60°C and observe if run times increase.
  • Open more radiators: Ensure enough radiators are open to absorb boiler output.

Technician actions:

  • Check flow and return NTC sensors for accuracy.
  • Verify correct pump speed and adjust if necessary.
  • Install or adjust an automatic bypass valve if required.
  • Review system design vs. boiler output and adjust settings (e.g., maximum power) on the Fondital PCB.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Automatic Bypass Valve
Check Price on Amazon