A03
Fondital Overheating / Safety Thermostat Intervention

Boiler stops with A03, temperature rises quickly, radiators very hot, pump may be noisy

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked primary heat exchanger on Fondital boiler, Air lock or low water circulation, Faulty or seized circulation pump, Defective safety thermostat or NTC sensor

How to Fix / Troubleshooting

Safety: Turn off the boiler and allow it to cool completely before touching any pipes. Do not remove any covers that require tools.

User checks:

  • System pressure: Check the pressure gauge on the Fondital boiler. It should typically be around 1.0–1.5 bar when cold. If below 1 bar, top up via the filling loop as per the user manual, then bleed radiators and recheck pressure.
  • Radiator valves: Ensure key radiators have valves open to allow circulation.
  • Bleed air: Bleed air from radiators and any accessible manual air vents. Trapped air can cause overheating.
  • Reset: After cooling and correcting pressure/air, reset the boiler once and observe operation.

Technician actions:

  • Check operation of the circulation pump (Fondital OEM pump or Grundfos/Wilo equivalent), freeing or replacing if seized.
  • Inspect and chemically clean or replace the primary heat exchanger if scaled or blocked.
  • Test the overheat thermostat and flow/return NTC sensors for correct resistance values.
  • Verify correct wiring and operation of the pump relay on the main PCB.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Circulation Pump
Check Price on Amazon