A07
Fondital
Fan / Airflow Control Fault
Boiler locks out with A07, fan may run continuously, no ignition sequence
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective flue fan motor on Fondital boiler, Blocked fan impeller, Faulty fan speed feedback (tachometer) signal, Wiring fault between fan and main PCB
How to Fix / Troubleshooting
Safety: Switch off the boiler and isolate from the mains. Do not remove the combustion cover.
User checks:
- Flue outlet: Confirm the external flue terminal is clear of obstructions.
- Reset: Try a single reset. If A07 reappears, professional diagnosis is required.
Technician actions:
- Measure supply voltage to the fan motor and check current draw.
- Inspect the fan impeller for dirt or foreign objects and clean or replace as needed.
- Verify the fan speed sensor / tachometer signal to the main PCB.
- Check the wiring harness and connectors between fan and Fondital main PCB.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Flue Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.