A14
Fondital
Gas Valve Modulation / Overpressure Fault
Boiler shows A14, burner stops, may occur during DHW draw-off, water temperature drops suddenly
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrectly adjusted gas valve on Fondital boiler, Faulty gas valve coil, Gas supply pressure outside specification, Defective main PCB gas control circuit
How to Fix / Troubleshooting
Safety: Gas adjustments must only be carried out by a licensed gas technician. Do not attempt to adjust the gas valve yourself.
User checks:
- Other gas appliances: Confirm they operate normally. If all appliances are affected, contact your gas supplier.
- Reset: Reset the boiler once. If A14 reappears, call a qualified technician.
Technician actions:
- Measure inlet and burner pressure and compare with Fondital data plate values.
- Check operation of the gas valve coils and replace the gas valve assembly if faulty.
- Verify correct modulation control signal from the main PCB.
- Perform combustion analysis and adjust the gas valve as per Fondital procedures.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Gas Valve Assembly
Check Price on Amazon
We may earn a commission from links on this page.