A14
Fondital Gas Valve Modulation / Overpressure Fault

Boiler shows A14, burner stops, may occur during DHW draw-off, water temperature drops suddenly

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrectly adjusted gas valve on Fondital boiler, Faulty gas valve coil, Gas supply pressure outside specification, Defective main PCB gas control circuit

How to Fix / Troubleshooting

Safety: Gas adjustments must only be carried out by a licensed gas technician. Do not attempt to adjust the gas valve yourself.

User checks:

  • Other gas appliances: Confirm they operate normally. If all appliances are affected, contact your gas supplier.
  • Reset: Reset the boiler once. If A14 reappears, call a qualified technician.

Technician actions:

  • Measure inlet and burner pressure and compare with Fondital data plate values.
  • Check operation of the gas valve coils and replace the gas valve assembly if faulty.
  • Verify correct modulation control signal from the main PCB.
  • Perform combustion analysis and adjust the gas valve as per Fondital procedures.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Gas Valve Assembly
Check Price on Amazon

We may earn a commission from links on this page.