A19
Fondital
Gas Supply Interruption / Lockout
Boiler displays A19, burner stops, may coincide with gas meter change or supply interruption
Advertisements
Possible Causes
Recent gas outage or meter replacement, Air in gas line to Fondital boiler, Gas isolation valve partially closed, Faulty gas meter regulator
How to Fix / Troubleshooting
Safety: If you smell gas, close the gas valve, ventilate the area, and contact your gas supplier immediately.
User checks:
- Gas valve: Ensure the gas isolation valve under the boiler is fully open.
- Other appliances: Check if gas hobs or other appliances work. If none work, contact your gas supplier.
- Reset attempts: After a known gas interruption, you may need 2–3 resets to purge air. If A19 persists, stop resetting.
Technician actions:
- Check gas supply pressure and stability at the boiler inlet.
- Inspect the gas valve and ignition sequence.
- Verify correct operation of the main PCB during ignition.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Gas Valve Assembly
Check Price on Amazon