A19
Fondital Gas Supply Interruption / Lockout

Boiler displays A19, burner stops, may coincide with gas meter change or supply interruption

Advertisements

Possible Causes

Recent gas outage or meter replacement, Air in gas line to Fondital boiler, Gas isolation valve partially closed, Faulty gas meter regulator

How to Fix / Troubleshooting

Safety: If you smell gas, close the gas valve, ventilate the area, and contact your gas supplier immediately.

User checks:

  • Gas valve: Ensure the gas isolation valve under the boiler is fully open.
  • Other appliances: Check if gas hobs or other appliances work. If none work, contact your gas supplier.
  • Reset attempts: After a known gas interruption, you may need 2–3 resets to purge air. If A19 persists, stop resetting.

Technician actions:

  • Check gas supply pressure and stability at the boiler inlet.
  • Inspect the gas valve and ignition sequence.
  • Verify correct operation of the main PCB during ignition.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Gas Valve Assembly
Check Price on Amazon