Condensate Discharge from Flue
Boiler flue terminal dripping water externally
Advertisements
Possible Causes
Normal condensate formation with poor drainage, Incorrect flue angle, Blocked condensate trap or pipe, Damaged flue seals
How to Fix / Troubleshooting
Safety: Condensate is mildly acidic; avoid prolonged skin contact. Do not dismantle the flue yourself.
- Assess amount: Light dripping in cold weather can be normal. Heavy or continuous dripping may indicate an issue.
- Check condensate pipe: Ensure the condensate pipe from the boiler to the drain is not blocked or frozen.
- Engineer tasks:
- Check flue angle to ensure it slopes correctly back to the boiler.
- Inspect and clear the condensate trap.
- Inspect flue seals and joints for leaks.
Persistent heavy dripping from the flue should be investigated to prevent staining and damage.